Abstract

This research describes the application of inverse analysis to estimate the thermal conductivity of a porous material using temperature measurements at the surfaces. Finite volume analysis code is implemented in MATLAB and it is utilized to solve the steady state, axisymmetric heat transfer governing energy equation. The analysis code is coupled with a numerical optimization method and utilized to predict thermal conductivity using the measurements. An experimental setup was developed to test a porous media composed of a mixture of small pellets and air. In experiments, temperature is measured at outer surface of copper tube. These data, serves as input for the inverse analysis. Inside this copper tube, an electric heater is placed at center along with porous mixture at annular gap. Location of the heater is affirmed centrally by special manufactured fixtures and by being attaching at both ends. In addition, thermocouples were installed on the surface of the heater to measure the temperature. Validation of the finite volume code was carried out with ANSYS® and with experimental data. Here, Semi Analytic Complex Variable Method (SACVM) is used to determine the sensitivity of the predicted material properties on error in temperature measurements. This information is used to determine the locations on the surface of the copper tube to take temperature measurements, so as to reduce the effect of measurement errors on the inversely determined parameter. Temperature data at our equidistant locations on copper tube are used as input to the inverse analysis code. The objective function id minimization of least squares error between measured experimental and predicted temperatures. Conjugate Gradient Method (CGM) is used to solve the resulting problem. Accurate sensitivities for the CGM were computed by SACVM. A heater with diameter of 0.0128 m, and a copper tube with a diameter of 0.0296 m are used for these experiments. Top and bottom of heater and copper tube are insulated to force radial direction heat transfer. Convective heat transfer coefficient is assumed as 8 W/m^2 K and ambient temperature is 295 K.

Keywords

Porous, Thermal conductivity, Inverse analysis

Disciplines

Aerospace Engineering | Engineering | Mechanical Engineering

Comments

Degree granted by The University of Texas at Arlington

27169-2.zip (2120 kB)

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.