Abstract

Vaginal prolapse is a common condition that affects a large number (approximately 3.3 million in the US) of women, mainly above the age of 50 years. The condition is characterized by the weakening and breakdown of the pelvic support structures such as muscles and connective tissues, leading to the dislodging and prolapse of pelvic organs. Current examinations of the pelvic tissue are manually performed by the physician who assesses its rigidity. These exams are subjective and offer qualitative rather than quantitative results of the state of the pelvic tissue. In this research, a complete system was conceptualized and designed to assess the biomechanical properties of the anterior vaginal wall in-vivo. The design mimics the palpating action performed by the physician on the vaginal wall to sense its rigidity. The reaction force profile resulting from the palpation is recorded and curve-fit to characterize the viscoelastic properties of the vaginal tissue. The data can later be used to provide a quantitative measure for the onset and progression of a condition by tracking the viscoelastic properties of the tissue. Considerations were taken into account to accommodate the environment constraints. Different sensing, actuation, and control technologies were explored and revised to improve the design. Finite element analysis (FEA) was performed to verify the structural safety of the hardware components. The system is controlled using National Instruments (NI) LabVIEW software and a NI myRIO controller. Additionally, a graphical user interface (GUI) in LabVIEW was developed and integrated to ease the operation of the device by a physician for in-vivo testing. The system was used to collect an initial sample set of in-vivo data from patients to verify the operational function of the prototyped system and identify areas in need of improvement.

Keywords

In-vivo medical diagnosis, Diagnostic system, Soft tissue characterization

Disciplines

Aerospace Engineering | Engineering | Mechanical Engineering

Comments

Degree granted by The University of Texas at Arlington

28379-2.zip (3783 kB)

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.