In today’s networking world, the usage of Servers and Data centers has been increasing significantly with a corresponding increase in power. The data center energy efficiency largely depends on thermal management of servers. Currently, air cooling is the most widely used thermal management technology in data centers. However, air cooling is starting to reach its limits due to high powered microprocessors and packaging. To overcome these limitations of air cooling in data centers, liquid cooling methods are starting to gain more traction. Thermal shadowing is the effect in which temperature of a cooling medium increases by carrying heat from one server and results in decreasing its heat carrying capacity due to a reduction in the temperature difference between the maximum junction temperature of successive heat sinks and incoming fluid. Thermal Shadowing is a challenge for both air and low velocity oil flow cooling and as such, both air and low velocity dielectric flow cooling technologies need to be optimized to get high energy efficiency. Low velocity oil flow cooling can be an effective technology for high thermal loads and high heat capacitance. Form factor study of 3rd generation server is another area of research in which impact of form factor on a maximum junction temperature and thermal resistance at the server level is documented. This work is to provide an insight to increase the rack density by reducing form factor of an existing server. This work can open up to more heat load per rack. The heat sink is a critical part for cooling effectiveness at server level. This work is to provide an efficient range of operation for heat sink with numerical and computational modelling of third generation open compute server. Optimization of heat sink can allow to cool high power density servers effectively. A parametric study is conducted and the thermal efficiency has been optimized.

Keywords

Data center cooling, Oil flow cooling, Thermal shadowing

Disciplines

Aerospace Engineering | Engineering | Mechanical Engineering

Comments

Degree granted by The University of Texas at Arlington

27258-2.zip (1216 kB)

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.