Graduation Semester and Year

2023

Language

English

Document Type

Dissertation

Degree Name

Doctor of Philosophy in Mechanical Engineering

Department

Mechanical and Aerospace Engineering

First Advisor

Panayiotis S. Shiakolas

Abstract

ABSTRACT: Minimally invasive procedures employ continuum manipulators, however, the internal human anatomy presents challenges relating to size, dexterity, and workspace for these manipulators. This research presents modeling, kinematic analysis, limited prototyping, and characterization of a micro-robotic manipulator to assess viscoelastic tissue properties of the bladder through transurethral palpation towards the diagnosis of bladder dysfunction, urinary incontinence, and early-stage bladder cancer. The proposed micro-robot consists of two subsystems; a unique 4mm outer diameter tendon-driven continuum segment from assembled “vertebrae” components with male and female snap-in features for joint assembly, an elastic tube encompassing each joint for controlled compliance and structural integrity that enters the bladder through the urethral, and an external segment with prismatic and hyper-spherical joints to ensure higher dexterity and manipulability. The developed kinematic analyses avoid motion discontinuities and singularities for the desired poses anywhere in the confined space of the interior of the bladder wall. The compliance of the tendon-driven proposed joint architecture was characterized as a function of the encompassing tube geometry and material properties using different modeling approaches (a strain energy model, a quasi-static model, and the principle of virtual work) and then applied to a multi-joint continuum segment. Limited functionality continuum modules with different joint lengths and multiple joints were prototyped for tension-bend angle characterization using a computer vision outfitted experimental setup. A comparison of the results from the experimental analysis and theoretical models shows high fidelity in predicting the continuum robot behavior. In addition, multiple existing polymer-based additive manufacturing technologies were investigated for improving the fabrication quality of the continuum segment components while the pose error is evaluated using geometric manufacturing uncertainties. This research demonstrates the proposed novel continuum segment module and its characterization for use in confined spaces in the human body for diagnostics purposes, employing the presented modeling approaches corroborated with experimental results.

Keywords

Compliant manipulator, Transurethral, Natural orifices, Robot, Design, Continuum, Elastic, Computer Vision, Inverse kinematics, Rapid prototyping

Disciplines

Aerospace Engineering | Engineering | Mechanical Engineering

Comments

Degree granted by The University of Texas at Arlington

31307-2.zip (56406 kB)

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.