Document Type
Presentation
Abstract
INTRODUCTION: Two different measurements, static lung volume and dynamic lung volume are used to report lung size, volume, and contractility. Spirometric Respiratory Tests are one way to measure these different lung values. Anaerobic Power is used for short bursts of high intensity power and is mainly measured using the Wingate Anaerobic Test (WAnT). The relationship between lung function and anaerobic power in healthy individuals is not completely understood. PURPOSE: The purpose of this study was to determine if lung volumes could be used to predict Wingate power. METHODS: Six women (W; age 24.7 ± 4.8 yrs.) and five men (M; age 24.2 ± 4.4 yrs.) that attended the University of Texas at Arlington, volunteered to participate in this study. The subjects performed a spirometric respiratory function test followed by a Wingate Anaerobic Test (WAnT). During the spirometric function test, each subject wore a nose clip and performed a series of breathing maneuvers into a mouthpiece attached to a spirometer. Lung function values including forced vital capacity (FVC), forced expiratory volume at one second (FEV1), and peak expiratory flow (PEF) were recorded. The WAnT required for subjects to pedal for 30 s at maximum speed against a constant resistance. The WAnT power parameters recorded include mean power (W), peak power (W), normalized mean power (W/kg), and normalized peak power (W/kg)). Statistical analyses were performed using SPSS to compute the correlation between WAnT power and lung. Multiple linear regression was used to compute prediction equations for WAnT power from FEV1, PEF, and FVC with alpha set at 0.05. RESULTS: Gender and lung function significantly predicted WAnT power, p < 0.05. The prediction equation for normalized peak power (W/kg) was PP = 4.12(Gender) −4.45 (FVC) + 6.58 (FEV1) −1.61(PEF) + 11.54, R2 = .82, SEE = 1.54. Similar equations were generated for normalized mean power, peak power and mean power in the WAnT from gender and lung function. Mean ± SD for each variable by gender were: FVC (W: 4.0 ± 0.9 L, M: 5.3 ± 1.1 L), FEV1 (W: 3.1 ± 0.6 L/sec, M: 3.6 ± 1.3 L/sec), PEF (W: 4.9 ± 1.8 L/min, M: 5.4 ± 2.8 L/min) and Wingate power parameters: MP (W: 395.8 ± 50.2 W, M: 586.8 ± 116.1 W), PP (W: 671.7 ± 123.5 W, M: 879.6 ± 228.2 W), MP/Wkg (W: 5.85 ± 0.6 W/Kg, M: 7.0 ± 2.0 W/Kg), PP/Wkg (W: 10.0 ± 2.4 W/Kg, M: 10.6 ± 3.6 W/Kg)). CONCLUSION: The results of this study indicate that lung volumes can be used to predict Wingate power in both men and women. Lung function and gender significantly explained 82 – 94% of the variance in Wingate power variables.
Disciplines
Kinesiology | Life Sciences
Publication Date
1-1-2015
License
This work is licensed under a Creative Commons Attribution-NonCommercial-Share Alike 4.0 International License.
Recommended Citation
Deam, Ashley, "Predicting Wingate Power From Lung Volumes" (2015). Kinesiology Student Research. 66.
https://mavmatrix.uta.edu/kinesiology_studentwork/66