Graduation Semester and Year

2011

Language

English

Document Type

Thesis

Degree Name

Master of Science in Electrical Engineering

Department

Electrical Engineering

First Advisor

Jung-Chih Chiao

Abstract

Reliable strain measurement plays a very important role in the damage detection of the mechanical and civil structures. It can also have a significant contribution in assisting the proper functioning of human body and organs. The current strain sensors and measurement systems have significant drawbacks in terms of high sensitivity to temperature, low gauge factor, low biocompatibility and bulky data acquisition/conditioning circuitry. These factors make the strain measurement unreliable and expensive. In this work, we have developed a laser micro-machined inter-digitated capacitive strain sensor which allowed us to overcome the limitations of existing strain sensing technologies. The structural health monitoring along with bladder volume sensing applications were targeted and the suitability of the sensor to these applications was verified. The capacitive strain sensor was made up of a low cost metal sheet which was micro-machined with a laser to form an inter-digitated structure. This structure was then encapsulated in a flexible, bio-compatible material which also acted as the dielectric. The connections were made on the metal with the help of a conductive paste to acquire the data. Design of the IDC with highest possible capacitance value with highest precision and repeatability was chosen for the desired applications. The inter-digitated structure was sensitive to stretching and bending resulting in capacitance changes. Modifications and amendments were made in the initial device to enhance its suitability and performance for structural health monitoring applications. The sensor was attached on to load bearing structures such as cantilevers and variation in initial capacitance value was checked experimentally for different strains. A simple circuitry was implemented to convert the capacitance changes in to frequency changes for ease of remote data transmission. Devices with flexible inter-digitated fingers were fabricated through laser micro-machining in order to improve their performance for in-vivo applications. The suitability of the new devices was shown experimentally for monitoring strain changes of structures such as the urinary bladder. The testing of these devices is done with a wireless, battery less circuitry to verify the working of the strain sensors for inside body applications. In this work, the design, fabrication, observations and results for the desired applications have been discussed.

Disciplines

Electrical and Computer Engineering | Engineering

Comments

Degree granted by The University of Texas at Arlington

Share

COinS