Abstract

Reinforced concrete pipes (RCP) are composite pipes which have been widely used in the industry for more than ten decades. They are generally used for sewerage, water drainage, and industrial waste water. There are two methods for designing the RCP so that it will bear the soil weight and the live load on it: Indirect design (ID) and direct design (DD) methods. ASTM C76 (1) classifies pipes into five categories. The five categories of pipes have been classified in order of ascending pipe diameter with their required load and reinforcement’s area. Typically, there are two reinforcement types: circumferential and longitudinal. Circumferential reinforcement is placed in two layers in the thickness of the pipe and the longitudinal reinforcements are placed around the circumferential reinforcements. All these reinforcements are placed in one layer, also known as cages. The task of placing two cages of reinforcement is not only tedious but also time consuming, expensive and sometimes unnecessary, especially for pipe classes III, IV and V. In this study, a three dimensional non-linear finite element modeling has been generated by using Abacus, Version 6.14-3, a program which is well known for non-linear finite element analysis, to simulate real pipe behavior for implementation of single cage instead of double cages reinforcements. Simulations were generated for classes III, IV and V with pipe diameters of 24, 36, 48, 60 and 72 in. Pipes were modeled by using three different single-cage reinforcement locations, in addition to the original double cage concrete pipe. After which a total of 80 simulations were conducted in order to compare the difference between the single and double cage behavior. In order to verify the simulations, three ASTM standard Three Edge Bearing tests were performed. Pipes were selected and tested according to ASTM C76 and ASTM C497 standards specifications. The study showed one cage of reinforcements in some pipes, satisfies all the ASTM requirements. Thereby making it possible for manufacturers to produce reinforced concrete pipes with a smaller amount of steel reinforcements per foot.

Keywords

Reinforced concrete pipes, Reinforcement cage reduction

Disciplines

Civil and Environmental Engineering | Civil Engineering | Engineering

Comments

Degree granted by The University of Texas at Arlington

26164-2.zip (8278 kB)

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.