ORCID Identifier(s)

0000-0003-0100-0654

Graduation Semester and Year

2020

Language

English

Document Type

Dissertation

Degree Name

Doctor of Philosophy in Civil Engineering

Department

Civil Engineering

First Advisor

Mohammad Najafi

Abstract

Buried culverts are important components of the highway infrastructure. Most large culverts are built decades ago from corrugated metal or reinforced concrete materials and now have reached their design lives. Trenchless renewal techniques can be utilized to enhance load carrying capacity of the existing deteriorated culverts and provide them a new design life. Spray applied pipe lining (SAPL) is a trenchless renewal methodology to renew damaged pipes and culverts by applying layers of liner on the interior surface of the deteriorated host culvert. The development of practical spray applied pipe linings could be of enormous benefit to the Departments of Transportation. Such linings could be a key strategy in extending service life and managing the future burden expected from the aging culverts and drainage structures. The SAPLs generally fall into two categories of cementitious and polymeric materials. Currently, there is no available standard for structural design of SAPLs. In absence of a standard design methodology, some vendors and contractors currently utilize the cured-in-place pipe (CIPP), ASTM F1216 methodology and others are using various classical analytical structural design equations developed for other purposes. To provide an understanding for development of a design methodology, the first objective of this dissertation was to investigate structural capacity of fully deteriorated invert large circular and arch corrugated metal pipes (CMPs) renewed with polymeric SAPL. The second objective of this dissertation was to compare the load carrying capacities of SAPL renewed circular and arch CMPs. The third objective of this dissertation was to check the applicability of ASTM F1216 CIPP design equation for SAPL method. The fourth objective of this dissertation was to develop a design methodology for structural application of polymeric SAPL using for renewal of large diameter (span larger than 36 in.) circular and arch culverts. To conduct this research, before application of SAPL, the inverts of CMP samples were cut to simulate fully deteriorated culverts in service conditions and to maximize the applied static load on the SAPL. The pipe samples were buried under two feet of soil cover. The performances of SAPL renewed CMPs were compared with a same size invert-cut bare CMP under same testing conditions. The results indicated that dependent on the thickness, application of polymeric SAPL can improve the structural capacity of a fully deteriorated invert CMP culvert. Under conditions of testing performed, a modified CIPP design equation, with an enhancement factor of 2.738, in a fully deteriorated pipe condition is applicable for polymeric SAPLs for structural renewal. An adapted AWWA C950 design equation is applicable for polymeric SAPLs. The moment of inertia in these equations needed to be calculated based on the corrugated profile.

Keywords

Spray Applied Pipe Lining, Soil box testing, Soil-pipe structure interaction, Corrugated metal pipes, Culvert, Full scale laboratory testing, Buried pipes, Polymeric SAPL

Disciplines

Civil and Environmental Engineering | Civil Engineering | Engineering

Comments

Degree granted by The University of Texas at Arlington

29398-1.zip (23106 kB)

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.