Author

Hongyue Guo

ORCID Identifier(s)

0000-0002-9279-2513

Graduation Semester and Year

2016

Language

English

Document Type

Dissertation

Degree Name

Doctor of Philosophy in Chemistry

Department

Chemistry and Biochemistry

First Advisor

Daniel W Armstrong

Abstract

In recent years, the paired ion electrospray ionization (PIESI) technique has been emerged as a promising alternative to overcome the inherent low sensitivity of negative ESI-MS. The current research focused on the further understanding of the mechanism of the enhanced sensitivity in PIESI based on previous studies, as well as novel applications of PIESI in sensitive and selective analysis of challenging anionic compounds. Specifically, this dissertation describes research in two areas: 1) The mechanism of PIESI in sensitive detection of anions was further investigated using two rational designed surface-active ion-pairing reagents. As compared to their corresponding non-surface-active ion-pairing reagents, the detection sensitivities obtained with surface-active ion-pairing reagents were further enhanced. It was found that surface activity plays a critical role in the detection sensitivity for anions with PIESI. 2) Novel applications of PIESI in trace analysis of anionic sugars, abused drug metabolites and dicamba residues were demonstrated in Chapter 3, 4 and 5 respectively. Chapter 3 demonstrates that PIESI provided LODs for anionic sugars by one to two orders of magnitude lower than negative ESI. Chapter 4 describes the development of a HPLC-MS/MS method based on PIESI for trace analysis of abused drugs in urine by detecting their glucuronate and sulfate conjugates. As compared to other reported negative ESI based methods, one to three orders of magnitude improvement in detection sensitivity was obtained with PIESI. Chapter 5 describes the application of PIESI for analysis of dicamba residues in complex raw agricultural commodities with enhanced sensitivity and selectivity. The performance of PIESI in reduction of matrix effects was demonstrated in Chapter 6. As compared to negative ion mode, PIESI were less susceptible to matrix effects in groundwater and urine. Overall, the PIESI strategy should be widely used for trace analysis of other types of anionic compounds and samples.

Keywords

Paired ion electrospray ionization (PIESI), Anionic compounds, High-performance liquid chromatography mass spectrometry (HPLC-MS), Detection sensitivity, Ion-pairing reagent

Disciplines

Chemistry | Physical Sciences and Mathematics

Comments

Degree granted by The University of Texas at Arlington

26917-2.zip (1944 kB)

Included in

Chemistry Commons

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.