Graduation Semester and Year

2017

Language

English

Document Type

Thesis

Degree Name

Master of Science in Biomedical Engineering

Department

Bioengineering

First Advisor

Hanli Liu

Abstract

The aim of this study was to utilize Diffused Correlation Spectroscopy (DCS) to design and develop real-time single and dual wavelength systems and assess the physiological impacts of exercises on blood perfusion. The study consisted of 4 parts. Part 1 was to Re-design and develop a real-time single wavelength DCS system, part 2 was to validate this system by a cross validation method with the help of a concurrent study alongside Doppler ultrasound. Part 3 was to design & develop a real-time dual wavelength DCS system and part 4 was to validate the dual wavelength DCS system. DCS is a developing non-obtrusive procedure to test profound tissue hemodynamics. DCS utilizes time-averaged intensity autocorrelation function for the fluctuations caused by moving scatterers (RBCs) in natural tissue. I introduced a software based autocorrelator framework to finish the securing and handling parts. I led approval considers on an intralipid phantom and human forearm. Both the studies demonstrated smooth decays which aid in showing signs of an improved fitting and subsequently more exact blood flow index (BFI). I appear that the software based autocorrelation framework can be a contrasting option to the traditional equipment based correlators in DCS frameworks with advantages, for example, adaptability in raw photon count information handling, data processing, minimal effort and low cost. Coordinate nonstop noninvasive estimation of neighborhood muscle blood stream in people stays constrained. Routine estimations of appendage blood stream, for example, Doppler ultrasound or venous impediment plethysmography, measure changes in mass channel stream and don't give provincial data. Near infrared diffused correlation spectroscopy (DCS) is a rising system for non-intrusive estimation of neighborhood muscle blood stream at the microvascular level. To better comprehend the qualities and restrictions of this novel approach, I played out an approval think about by looking at muscle blood stream changes measured by DCS and Doppler ultrasound during a small exercise. The design and development of a real-time dual Wavelength DCS system consisted of 2 laser sources. An optical switch was used to toggle the light between laser 1 and laser 2. With this dual wavelength system conc. of HbO (Oxy hemoglobin) & conc. of Hb (de-Oxy hemoglobin) can be calculated along with the other parameters like rBFI (relative blood flow index), dOD (delta Optical density) and total intensity of the detected photons. I led validation studies on intralipid phantom and human forearm (arm cuff measurement). Both the studies demonstrated smooth decays which aid in showing signs of an improved fitting for rBFI and conc. of HbO (Oxy hemoglobin) & conc. of Hb (de-Oxy hemoglobin) was also obtained in real-time.

Keywords

DCS, Design and Development

Disciplines

Biomedical Engineering and Bioengineering | Engineering

Comments

Degree granted by The University of Texas at Arlington

31705-2.zip (4098 kB)

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.